1 3/4"x11 7/8" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:47 PM
|
Design Values
|
|
|
|
-
SclMaterialId
392
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
11.875
-
DepthText
11 7/8
-
LegacyMaterialId
EWL~TrusJoistLVL_392
-
MaterialGuid
23adafcb-bcad-4df2-a50f-13bf7767c2ac
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_392
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
False
-
WeightPounds
6.5
-
WidthInches
1.75
-
WidthText
1 3/4
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:47 PM
-
LastModifiedUserId
0
|
|
|
1 3/4"x14" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:47 PM
|
Design Values
|
|
|
|
-
SclMaterialId
394
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
14
-
DepthText
14
-
LegacyMaterialId
EWL~TrusJoistLVL_394
-
MaterialGuid
d03b3113-48bc-4845-a12c-3eb5ac5a895e
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_394
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
False
-
WeightPounds
7.7
-
WidthInches
1.75
-
WidthText
1 3/4
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:47 PM
-
LastModifiedUserId
0
|
|
|
2 11/16x9 1/4 2.0P-LAM PSL
|
2.0P-LAM PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:47 PM
|
Design Values
|
|
|
|
-
SclMaterialId
395
-
SclCommonId
1
-
SclSeriesId
13
-
SclTypeId
3
-
DepthInches
9.25
-
DepthText
9 1/4
-
LegacyMaterialId
EWL~TrusJoistLVL_395
-
MaterialGuid
0151f0d2-6f08-450f-85f6-2188d8e8e609
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_395
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
False
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
7.8
-
WidthInches
2.6875
-
WidthText
2 11/16
-
SecurityId
223
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:47 PM
-
LastModifiedUserId
0
|
|
|
2 11/16x9 1/2 2.0P-LAM PSL
|
2.0P-LAM PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:47 PM
|
Design Values
|
|
|
|
-
SclMaterialId
396
-
SclCommonId
1
-
SclSeriesId
13
-
SclTypeId
3
-
DepthInches
9.5
-
DepthText
9 1/2
-
LegacyMaterialId
EWL~TrusJoistLVL_396
-
MaterialGuid
007a57fa-5eb3-47d6-a746-7962f4c386ce
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_396
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
False
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
8
-
WidthInches
2.6875
-
WidthText
2 11/16
-
SecurityId
223
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:47 PM
-
LastModifiedUserId
0
|
|
|
2 11/16x11 1/4 2.0P-LAM PSL
|
2.0P-LAM PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:47 PM
|
Design Values
|
|
|
|
-
SclMaterialId
397
-
SclCommonId
1
-
SclSeriesId
13
-
SclTypeId
3
-
DepthInches
11.25
-
DepthText
11 1/4
-
LegacyMaterialId
EWL~TrusJoistLVL_397
-
MaterialGuid
abbad731-8af9-4636-952b-60b24212d8cd
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_397
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
False
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
9.5
-
WidthInches
2.6875
-
WidthText
2 11/16
-
SecurityId
223
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:47 PM
-
LastModifiedUserId
0
|
|
|
2 11/16x11 7/8 2.0P-LAM PSL
|
2.0P-LAM PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:47 PM
|
Design Values
|
|
|
|
-
SclMaterialId
398
-
SclCommonId
1
-
SclSeriesId
13
-
SclTypeId
3
-
DepthInches
11.875
-
DepthText
11 7/8
-
LegacyMaterialId
EWL~TrusJoistLVL_398
-
MaterialGuid
69667c58-5f6a-4ed6-86d6-55458d97d0c3
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_398
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
False
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
10
-
WidthInches
2.6875
-
WidthText
2 11/16
-
SecurityId
223
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:47 PM
-
LastModifiedUserId
0
|
|
|
2 11/16x14 2.0P-LAM PSL
|
2.0P-LAM PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:47 PM
|
Design Values
|
|
|
|
-
SclMaterialId
399
-
SclCommonId
1
-
SclSeriesId
13
-
SclTypeId
3
-
DepthInches
14
-
DepthText
14
-
LegacyMaterialId
EWL~TrusJoistLVL_399
-
MaterialGuid
dbcc6497-e6d1-4dbf-b983-0f35c463c76d
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_399
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
False
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
11.8
-
WidthInches
2.6875
-
WidthText
2 11/16
-
SecurityId
223
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:47 PM
-
LastModifiedUserId
0
|
|
|
2 11/16x16 2.0P-LAM PSL
|
2.0P-LAM PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:47 PM
|
Design Values
|
|
|
|
-
SclMaterialId
400
-
SclCommonId
1
-
SclSeriesId
13
-
SclTypeId
3
-
DepthInches
16
-
DepthText
16
-
LegacyMaterialId
EWL~TrusJoistLVL_400
-
MaterialGuid
ef43be4c-49e9-464a-81e6-5f2520b0158f
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_400
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
False
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
13.4
-
WidthInches
2.6875
-
WidthText
2 11/16
-
SecurityId
223
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:47 PM
-
LastModifiedUserId
0
|
|
|
2 11/16x18 2.0P-LAM PSL
|
2.0P-LAM PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:47 PM
|
Design Values
|
|
|
|
-
SclMaterialId
401
-
SclCommonId
1
-
SclSeriesId
13
-
SclTypeId
3
-
DepthInches
18
-
DepthText
18
-
LegacyMaterialId
EWL~TrusJoistLVL_401
-
MaterialGuid
a2afed0d-3515-4fc1-af2d-c5ded72bb5c6
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_401
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
False
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
15.1
-
WidthInches
2.6875
-
WidthText
2 11/16
-
SecurityId
223
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:47 PM
-
LastModifiedUserId
0
|
|
|
3 1/2"x9 1/4" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
402
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
9.25
-
DepthText
9 1/4
-
LegacyMaterialId
EWL~TrusJoistLVL_402
-
MaterialGuid
04383756-3504-44ec-9018-4cbb1a38ee11
-
HoleRules
0
-
LegacyMaterialId
EWL~TrusJoistLVL_402
-
IgnoreShearDeflect
False
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
True
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
10.097916666666666
-
WidthInches
3.5
-
WidthText
3 1/2
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
3 1/2"x9 1/2" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
404
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
9.5
-
DepthText
9 1/2
-
LegacyMaterialId
EWL~TrusJoistLVL_404
-
MaterialGuid
dccc2098-2070-47a5-af0a-161f427ae676
-
HoleRules
0
-
LegacyMaterialId
EWL~TrusJoistLVL_404
-
IgnoreShearDeflect
False
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
True
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
10.370833333333334
-
WidthInches
3.5
-
WidthText
3 1/2
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
3 1/2"x11 1/4"2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
405
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
11.25
-
DepthText
11 1/4
-
LegacyMaterialId
EWL~TrusJoistLVL_405
-
MaterialGuid
2ed99f4e-cff8-4be2-9a68-b530017f9766
-
HoleRules
0
-
LegacyMaterialId
EWL~TrusJoistLVL_405
-
IgnoreShearDeflect
False
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
True
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
12.28125
-
WidthInches
3.5
-
WidthText
3 1/2
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
3 1/2"x11 7/8"2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
407
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
11.875
-
DepthText
11 7/8
-
LegacyMaterialId
EWL~TrusJoistLVL_407
-
MaterialGuid
c87fffc1-1490-4966-af1c-80d4b9473858
-
HoleRules
0
-
LegacyMaterialId
EWL~TrusJoistLVL_407
-
IgnoreShearDeflect
False
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
True
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
12.963541666666666
-
WidthInches
3.5
-
WidthText
3 1/2
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
3 1/2"x14" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
409
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
14
-
DepthText
14
-
LegacyMaterialId
EWL~TrusJoistLVL_409
-
MaterialGuid
b85bbaaf-8893-452a-89af-7c0e9716dfd6
-
HoleRules
0
-
LegacyMaterialId
EWL~TrusJoistLVL_409
-
IgnoreShearDeflect
False
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
15.283333333333333
-
WidthInches
3.5
-
WidthText
3 1/2
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
3 1/2"x16" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
411
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
16
-
DepthText
16
-
LegacyMaterialId
EWL~TrusJoistLVL_411
-
MaterialGuid
31774177-25e3-4c9b-84b8-ed90e0f87aa6
-
HoleRules
0
-
LegacyMaterialId
EWL~TrusJoistLVL_411
-
IgnoreShearDeflect
False
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
17.466666666666665
-
WidthInches
3.5
-
WidthText
3 1/2
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
3 1/2"x18" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
412
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
18
-
DepthText
18
-
LegacyMaterialId
EWL~TrusJoistLVL_412
-
MaterialGuid
7fda0242-223d-4ee8-b043-ef56820b6f4b
-
HoleRules
0
-
LegacyMaterialId
EWL~TrusJoistLVL_412
-
IgnoreShearDeflect
False
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
19.65
-
WidthInches
3.5
-
WidthText
3 1/2
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
3 1/2"x18 3/4" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
413
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
18.75
-
DepthText
18 3/4
-
LegacyMaterialId
EWL~TrusJoistLVL_413
-
MaterialGuid
383e7d34-ad67-45bc-b156-26494f6eebbe
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_413
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
False
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
20.5078125
-
WidthInches
3.5
-
WidthText
3 1/2
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
3 1/2"x19" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
414
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
19
-
DepthText
19
-
LegacyMaterialId
EWL~TrusJoistLVL_414
-
MaterialGuid
be04aee0-5dd6-4fad-83f3-62cd2ceb11b6
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_414
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
False
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
20.7416667
-
WidthInches
3.5
-
WidthText
3 1/2
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
3 1/2"x22" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
415
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
22
-
DepthText
22
-
LegacyMaterialId
EWL~TrusJoistLVL_415
-
MaterialGuid
bc48bb0c-39ad-4655-a042-d8cad851fa41
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_415
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
False
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
False
-
WeightPounds
24.1
-
WidthInches
3.5
-
WidthText
3 1/2
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
3 1/2"x24" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
416
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
24
-
DepthText
24
-
LegacyMaterialId
EWL~TrusJoistLVL_416
-
MaterialGuid
e6f9268e-914f-4d06-945b-e5d550fd3dfd
-
HoleRules
100
-
LegacyMaterialId
EWL~TrusJoistLVL_416
-
IgnoreShearDeflect
True
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
False
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
False
-
WeightPounds
26.3
-
WidthInches
3.5
-
WidthText
3 1/2
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
5 1/4"x9 1/4" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
417
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
9.25
-
DepthText
9 1/4
-
LegacyMaterialId
EWL~TrusJoistLVL_417
-
MaterialGuid
fad9b55f-b526-4f72-9ebf-7adb9ce9ec64
-
HoleRules
0
-
LegacyMaterialId
EWL~TrusJoistLVL_417
-
IgnoreShearDeflect
False
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
True
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
15.185416666666667
-
WidthInches
5.25
-
WidthText
5 1/4
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
5 1/4"x9 1/2" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
418
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
9.5
-
DepthText
9 1/2
-
LegacyMaterialId
EWL~TrusJoistLVL_418
-
MaterialGuid
7d1ecff6-00e5-44a7-9896-6f82b06c1342
-
HoleRules
0
-
LegacyMaterialId
EWL~TrusJoistLVL_418
-
IgnoreShearDeflect
False
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
True
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
15.595833333333333
-
WidthInches
5.25
-
WidthText
5 1/4
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
5 1/4"x11 1/4"2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
419
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
11.25
-
DepthText
11 1/4
-
LegacyMaterialId
EWL~TrusJoistLVL_419
-
MaterialGuid
f9ea40cf-25fd-4bf1-b88f-777411778d25
-
HoleRules
0
-
LegacyMaterialId
EWL~TrusJoistLVL_419
-
IgnoreShearDeflect
False
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
True
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
18.46875
-
WidthInches
5.25
-
WidthText
5 1/4
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
5 1/4"x11 7/8"2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
420
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
11.875
-
DepthText
11 7/8
-
LegacyMaterialId
EWL~TrusJoistLVL_420
-
MaterialGuid
7d3ad45b-94d5-4482-8bfb-8e266050f77a
-
HoleRules
0
-
LegacyMaterialId
EWL~TrusJoistLVL_420
-
IgnoreShearDeflect
False
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
True
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
19.494791666666668
-
WidthInches
5.25
-
WidthText
5 1/4
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|
|
|
5 1/4"x14" 2.0P-LAM PSL
|
2.0E Parallam PSL
|
Trus Joist LVL
|
|
3/27/2025 2:45:48 PM
|
Design Values
|
|
|
|
-
SclMaterialId
421
-
SclCommonId
1
-
SclSeriesId
12
-
SclTypeId
3
-
DepthInches
14
-
DepthText
14
-
LegacyMaterialId
EWL~TrusJoistLVL_421
-
MaterialGuid
94d5d87b-4fe8-48cb-9eee-18aee628a82f
-
HoleRules
0
-
LegacyMaterialId
EWL~TrusJoistLVL_421
-
IgnoreShearDeflect
False
-
IsPlanable
False
-
IsRippable
False
-
OcMaxFloorInches
24
-
OcMaxRoofInches
24
-
OcMinFloorInches
12
-
OcMinRoofInches
12
-
UseBeam
True
-
UseColumn
False
-
UseFloor
True
-
UseGirder
True
-
UseJoist
True
-
UseRoof
True
-
UseTrussChord
False
-
UseWallStud
False
-
UseNonResidential
True
-
WeightPounds
22.983333333333334
-
WidthInches
5.25
-
WidthText
5 1/4
-
SecurityId
100
-
IsNewSecuritySplit
-
LastModifiedDateTime
3/27/2025 2:45:48 PM
-
LastModifiedUserId
0
|